  • [Cath/Angio/X-ray] 2003 Allura Flat Panel Detector cathlab Date:2012-08-03 00:54:42 Hits:191

    2003 Allura Flat Panel Detector cathlab...

  • [Cath/Angio/X-ray] PHILIPS 2001 Integris H5000 Date:2012-08-03 00:01:23 Hits:107

    This is now a parts system. All electronics are available. 2006 MRC-200 0580 tube. 9 image intensifier. Almost new table consoles. Philips 18 LCD monitors. Control room monitor and consoles....

  • [CT] 2004 Philips Acqsim Date:2012-08-02 23:46:50 Hits:110

    Philips Acqsim Wide bore CT manufactured in 2004 with a Dunlee tube that was installed on 9/5/2007. It has 382,167 scan seconds. Rrunning on rev 4.0.1 software. Serial number is 3155. System is still up and running and will be available in ...

  • [CT] 2007 Philips Brilliance 16 Slice Air-cooled CT Date:2012-08-02 23:42:53 Hits:148

    We own this 2007 Philips Brilliance 16 Slice CT, Air-cooled, MRC600, 8.0 MHU tube. Tube information:96490 exposures on tube in 221121 scan seconds. SN: 45758. 3D MPR Cardiac Rapidview Doseview Bolus Timing Bolus Tracking Spiral auto start...

  • [CT] TOSHIBA Aquilion 16 CT Scanner Date:2012-08-02 23:40:04 Hits:310

    Manufactured in 2004. Version 1.71VR002. Gantry total slice count 723,651, Tube was replaced in 2010 with slice count 127,481. optional menu: Real Tech PC Transfer soft COT-37D Real 3D Color 4D Dental Package Head flowing system Dicom SCP...

  • [Cath/Angio/X-ray] 1998 GE Advantx LCA-C(LC+) still installed Date:2012-05-14 22:38:32 Hits:96

    1997 GE Advantx LCA-C still installed. To be deinstalled in August 2012...

  • [Cath/Angio/X-ray] 2000 Siemens Coroskop still installed Date:2012-05-14 21:01:25 Hits:126

    Still up and running in a hospital in Northeast. To be deinstalled soon. Serial Number: 4105. Hicor, Acom M. 9" II. In very good working and cosmetic condition. ...

  • [Nuclear Medicine] 2004 Mobile Biograph Duo PET/CT Date:2012-05-14 20:57:42 Hits:147

    We own this Siemens Biograph Duo LSO PET/CT Mobile. Biograph Duo manufactured in 2004. Mobile trailer manufactured by Medical Coaches in 2004. On-board Hot lab and patient areas. Length:46'(14.0M), Width: 102"(10.1M, Height: 13'5"(4.05M), R...

  • [CT] 2005-2006 Sensation 16 Date:2012-05-14 20:55:08 Hits:132

    Sensation 16 Manufactured in Dec 2005. Straton x-ray with 130,000 scan seconds,Patient table cardiac,18.1 Flat screen 1280x1024 LCD. software keys: Dental, Volume Redering, CAP3D Editor, Cardio Pro, Cardio Retro, DMS. SOMARIS/5, Syngo, HIS/...

  • [CT] 2002 Siemens Sensation 4 Date:2012-05-14 20:17:34 Hits:154

    Siemens Sensation 4 manufactured in 2002. Akron tube was manufactured in Oct 2010. The system was in good working condition at the time of removal in early March. It is now stored in a warehouse in Midwest. ...